R410A Phase Out Updates - What's the Alternative?
HVAC TV21 Feb 2023

R410A Phase Out Updates - What's the Alternative?

In this episode, we discuss the impending phase-out of R410A refrigerant. As the industry shifts toward more environmentally friendly alternatives, we compare the physical properties of two viable replacements: R32 and R454B.

We delve into the benefits and drawbacks of each refrigerant, exploring factors such as its global warming potential, energy efficiency, and flammability.

Join us as we explore the complex world of refrigerants and the exciting innovations driving the HVAC industry forward.

Refrigerants play a critical role in the functioning of air conditioning and refrigeration systems. They are responsible for transferring heat from the indoor or outdoor space to the refrigeration unit, allowing for temperature control. However, the impact of refrigerants on the environment is a growing concern. Many commonly used refrigerants have high global warming potential (GWP), contributing to climate change. In recent years, there has been a push to develop and adopt refrigerants with lower GWP, leading to the emergence of new refrigerants with unique properties.

Two such refrigerants are R32 and R454B. R32 is a pure hydrofluorocarbon (HFC) refrigerant, while R454B is a blend of HFC and hydrofluoroolefin (HFO) refrigerants. While both of these refrigerants offer lower GWP, they have unique properties that distinguish them from each other.

Both have similar performance to R410A. Both have a similar performance to each other. Both are classified as A2L, mildly flammable refrigerants. Both have a lower GWP than R410A.

R32 is a single-component refrigerant. It is a mildly flammable A2L refrigerant, meaning it can ignite in the presence of an ignition source but only under certain conditions. R32 has a low GWP of 675, making it an attractive option for environmentally conscious companies.

R454B is a zeotropic blend of HFC and HFO refrigerants, 69% R32 and 31% R1234yf. It is a mildly flammable A2L refrigerant with a low GWP of 466. R454B was developed as a potential replacement for high-GWP refrigerants like R410A.


Denne episoden er hentet fra en åpen RSS-feed og er ikke publisert av Podme. Den kan derfor inneholde annonser.

Episoder(201)

Better Than Boring: Heat Exchangers 101 with Danfoss’ Vic Marinich

Better Than Boring: Heat Exchangers 101 with Danfoss’ Vic Marinich

In this episode of HVAC TV, we sit down with Vic Marinich from Danfoss to talk all things heat exchangers—what they are, why they matter, and how they’re evolving to meet the demands of modern HVAC sy...

23 Sep 202539min

Inside the Loudest Room in HVAC: JADEC’s Air Handler & Reverberant Lab

Inside the Loudest Room in HVAC: JADEC’s Air Handler & Reverberant Lab

In the finale of JADEC: The Tour, Tony Mormino and Rob Tanner step inside YORK’s Air Handler Lab and the massive reverberant sound chamber — where fans and air handlers are pushed to the limits of air...

16 Sep 202523min

The R8 Compressor: How YORK Recovered Capacity in a 3,000-Ton Chiller

The R8 Compressor: How YORK Recovered Capacity in a 3,000-Ton Chiller

In Part 7 of the JADEC Tour, Rob Tanner and Tony Mormino dig into one of YORK’s latest innovations — the R8 compressor. Built to offset capacity losses from the transition to low-GWP refrigerants, thi...

9 Sep 20258min

The Quietest Chiller in the World (Because… No Compressor)

The Quietest Chiller in the World (Because… No Compressor)

In this episode of the JADEC Tour, we step inside the hemi-anechoic sound chamber to test the quietest centrifugal chiller in the industry — mostly because it doesn’t have a compressor installed (yet)...

2 Sep 20255min

Real-World HVAC Construction, Retrofits & Sales Lessons with Art Hoover

Real-World HVAC Construction, Retrofits & Sales Lessons with Art Hoover

Tony talks with Art Hoover of Matrix HG Construction about Bay Area HVAC challenges, from electrification costs to compressor retrofits. They dive into design-build vs. plan-spec, post-COVID building ...

26 Aug 202544min

So You Want to Be a Chiller Design Engineer?

So You Want to Be a Chiller Design Engineer?

In this episode of the JADEC Tour, we go behind the scenes with YORK chiller product engineers Brady Schulz and Austin Reth to uncover what it really takes to work in HVAC product development. From le...

19 Aug 20258min

VFDs Explained (Finally): Everything You Were Afraid to Ask

VFDs Explained (Finally): Everything You Were Afraid to Ask

Tony Mormino is joined by Louie and Peter from ABB to break down Variable Frequency Drives—what they are, how they save energy, and why they’re essential in today’s HVAC systems. From fan laws to harm...

12 Aug 202541min

Press Fittings, Piping Failures & Star Wars: A Conversation with Sean Kelleher from RLS

Press Fittings, Piping Failures & Star Wars: A Conversation with Sean Kelleher from RLS

In this episode of HVAC TV, Tony sits down with Sean Kelleher, Director of Engineering at RLS (Rapid Locking Systems), to talk about one of the most critical—and often overlooked—aspects of HVAC: refr...

5 Aug 202537min

Populært innen Business og økonomi

stopp-verden
lydartikler-fra-aftenposten
dine-penger-pengeradet
e24-podden
rss-penger-polser-og-politikk
rss-borsmorgen-okonominyhetene
rss-skravla-gar
pengepodden-2
livet-pa-veien-med-jan-erik-larssen
rss-pa-konto
tid-er-penger-en-podcast-med-peter-warren
utbytte
okonomiamatorene
rss-markedspuls-2
pengesnakk
morgenkaffen-med-finansavisen
lederpodden
finansredaksjonen
stormkast-med-valebrokk-stordalen
liberal-halvtime